HS Code |
228859 |
| Product Name | Xylenol Orange (Reagent) |
| Chemical Formula | C31H32N2O13S |
| Molar Mass | 672.65 g/mol |
| Appearance | Reddish-orange powder |
| Solubility | Soluble in water |
| Ph Range | 1.2 - 2.2 (as indicator) |
| Melting Point | Decomposes before melting |
| Storage Temperature | Room temperature, tightly sealed |
| Main Use | Metal ion indicator in titrations |
| Cas Number | 3618-43-7 |
| Synonyms | XO, Mordant Orange 1 |
| Sensitivity | Highly sensitive to metal ions |
| Hazard Statements | Irritant to skin and eyes |
| Color Change | Red to yellow (in presence of metal ions) |
| Spectral Maximum | 433 nm (in aqueous solution) |
As an accredited Xylenol Orange(Reagent) factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The packaging for Xylenol Orange (Reagent) contains 25 grams, sealed in a labeled amber glass bottle to ensure product stability. |
| Shipping | Xylenol Orange (Reagent) is shipped in tightly sealed containers to prevent contamination and moisture exposure. It should be packaged with appropriate labeling, handled with care, and transported under dry, cool conditions, away from incompatible substances. All shipments comply with relevant chemical safety and transport regulations to ensure safe delivery. |
| Storage | Xylenol Orange (Reagent) should be stored in a tightly sealed container at room temperature, ideally between 15–25°C, in a cool, dry, and well-ventilated area away from direct sunlight and moisture. Keep it away from incompatible substances such as strong oxidizers and acids. Ensure proper labeling and restrict access to authorized personnel. Avoid sources of ignition and store it in accordance with local regulations. |
Competitive Xylenol Orange(Reagent) prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615380400285 or mail to sales2@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8615380400285
Email: sales2@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
In our production halls, we’ve watched Xylenol Orange evolve from an academic curiosity into a staple for analytical chemistry and industrial quality assurance. Our facility carries out the entire process, batch by batch, starting from the precise weighing of raw aromatic ingredients to the rotary evaporators that give us the fine, orange-hued crystalline powder laboratories demand. Every unit we ship reflects both the rigor of modern organic synthesis and the relentless focus that comes with direct manufacturing oversight.
Our experience reaches back through years of analytical testing, collaborating with both universities and commercial labs, so every improvement in Xylenol Orange’s purification has come with hands-on troubleshooting and practical constraint. We know the sharpness expected in titrimetric indicators and the color consistency scientists rely on for clear endpoint detection. We’ve eliminated batch variability by tuning our filtration steps, monitoring every crystallization, and carefully controlling drying conditions to reduce risk of contaminant carryover. The result is a product that sees success not only in water hardness titrations but also in a range of research into rare-earth metals—applications where the slightest impurity can obscure results.
Our Xylenol Orange (Reagent Grade) comes as a fine, easy-to-disperse powder, typically supplied in tightly sealed amber glass containers for optimal shelf stability. Each batch is labeled by date of manufacture and lot number, allowing precise traceability—an important safeguard our industrial clients appreciate during audits or method development studies.
Consistent purity stays our guiding principle. UV-Vis absorption matches the signature peaks needed for colorimetric and spectrophotometric applications, and we test for trace iron and copper since these can interfere with complexometric titrations. Water solubility meets practical demands for quick preparation; our product disperses cleanly at room temperature, sparing customers the frustration that comes with gritty, under-refined material.
Appearance, moisture content, and residual solvents undergo statistical checks during every run. We’ve worked to keep batch-to-batch variation in color intensity within narrow margins—a simple but crucial quality feature when technicians may judge endpoints visually in the field or in fast-paced QC labs. Portions of each batch are archived long-term in our retention sample vaults, a commitment we keep to simplify quality investigations if end users raise concerns down the line.
We manufacture Xylenol Orange with a clear appreciation for its unique role in analytical chemistry. Its distinctive orange-to-yellow color shift in the presence of metal ions makes it invaluable for EDTA titration, particularly in the determination of calcium, magnesium, and even heavy metals like uranium or thorium—metals that challenge the selectivity of less robust indicators.
Over the years, we’ve seen its adoption extend beyond water analysis labs and into quality-control routines for ceramics, pharmaceuticals, and metallurgy. For those working with trace-level metals, background purity cannot be an afterthought. We’ve tested our batches against trace analytical methods (AAS, ICP-MS, and standardized colorimetric titration) to ensure false positives don’t compromise results. We’ve also paid attention to the needs of educational labs, recognizing that clear color contrast and reliable visual endpoints help build technical skill and reduce uncertainty for students learning the fundamentals of analytical technique.
Our customers use Xylenol Orange in both manual and automated analyses, and we routinely advise labs setting up auto-samplers or photometric detectors on preparation routines, since improperly dissolved reagent or presence of colloidal particles can skew automated readings. Real-life troubleshooting in high-throughput industrial applications has led us to prioritize both rapid dissolution and low particulate residue in production—these details often escape attention until they appear as problems in the lab.
We know that providers outside the manufacturing sphere sometimes outsource production or relabel other companies’ materials. In contrast, our hands remain on every stage from raw feedstock to final QC. Xylenol Orange isn’t just another item in an online catalog for us—its performance in complexometric titration depends on a precision that sometimes gets lost in mass-scale, third-party supply chains.
The differences start with our proprietary purification train. We run multiple filtration and recrystallization steps, guided by UPLC and FTIR monitoring, not just basic melting-point checks. By keeping the operation in-house, we respond quickly to any deviation—if a colorimetric response falls out of range, our technicians halt distribution and resolve issues before any batch is released. Because we work in small custom lots as well as larger commercial scales, customers benefit from flexible order quantities without sacrificing quality.
We often get samples sent in from companies dissatisfied with “pharmaceutical grade” or imported indicator powders. We evaluate these side-by-side under our spectrophotometers. Off-spec material routinely shows background fluorescence, off-hue shades, or inconsistent endpoint triggers. These failures often come from insufficient purification, excessive exposure to ambient moisture, or poor handling during packing. The success of our approach lies not only in purity but also in controlled particle sizing and freshness. Analysts appreciate that our material dissolves cleanly into solution, free from unreactive clumps or legacy contaminants.
Many labs get frustrated when non-manufacturing sources can’t trace the history of a given lot or provide clear guidance tailored to unusual analytical problems. As manufacturers, we take responsibility for every gram that leaves our plant. Our support team doesn’t just read from a script—we recruit experienced chemists and application specialists who have spent years at the bench troubleshooting exactly the kinds of issues end-users encounter.
From the beginning, we built our production around direct customer feedback. Early on, users pointed out inconsistencies caused by minor residual solvents; QC staff in battery plants noticed weak color shifts when titrating specialty alloys. Resolving those issues led us to invest in thicker glass packaging, triple-layer vacuum drying, and fast-response recalibration of our methods. Our quality control draws from on-the-ground experience, not abstract theory. Meeting scientists at trade shows or hosting site visits often gives us crucial perspectives; we bring these back to the lab and look for ways to address them at the manufacturing level.
Quality standards aren’t just numbers on paper here: every deviation triggers a transparent investigation, shared with our partners when relevant. We record and publish impurity profiles for each lot, even if the levels fall below current regulatory thresholds. Sometimes we’ll revisit our extraction protocols based on a single feedback report or a new standard emerging from ISO or ASTM committees. This mindset pushes us to keep improving, and we welcome direct partnerships with research groups or industrial consortia seeking performance guarantees.
The stories we hear in technical support remind us why vigilance over quality matters. A researcher tracing trace copper in river sediments may need to distinguish sub-ppm differences with confidence. Their method often relies on Xylenol Orange as a final indicator, and the clarity of endpoint color can decide whether a regulatory limit gets flagged. If hidden impurities or unpredictable color changes appear, the work becomes compromised, sometimes forcing entire batches of testing to be redone.
Industrial water treatment facilities run routine titrations every hour to monitor mineral content, with little time for reagent troubleshooting. A single batch of poorly purified Xylenol Orange could distort results across hundreds of readings, causing process errors or expensive recalibrations in downstream equipment. For these users, reliability isn’t a sales pitch—it’s part of keeping production running and legal compliance intact.
In academic labs, clarity and reproducibility help train future chemists in best practices. When students recognize the distinct hues that accompany metal-ligand binding through Xylenol Orange, they gain confidence in their technique. Foggy, low-grade indicators undermine both learning and real analytical output. Teachers have told us that switching to our reagent version eliminated confusion and reduced ambiguous grades in lab reports.
Routine calibration of analytical equipment uses tightly characterized indicator solutions. Laboratories that standardize their protocols with internally consistent Xylenol Orange save hours tracking down unknown drift or equipment error. Early in our process development, we encouraged calibration in parallel with reference materials, so users could compare our batches against NIST-verified samples. Problems with off-brand indicators often become visible only after hundreds of runs, costing labs both money and trust with clients. Our tightly controlled manufacturing aims to keep long-term drift and false endpoints from ever entering the workflow.
Some of the most sophisticated applications push Xylenol Orange outside traditional settings. Metallurgical plants may titrate for rare-earth content at extreme pH, or research labs may use photometric analysis at high throughput. For every new use case, we collaborate directly with the client, adapting batch size and packaging style as needed. Whether it’s preparing sub-millimolar solutions by weight or batch-dispensing for robotic analysis stations, our team guides customers on optimal handling and preparation.
Our in-lab studies show that even minor shifts in particle size or residual solvent content—often missed by basic specification sheets—can affect endpoint clarity and spectrophotometer readings. By controlling these variables in-house, we protect end users against both obvious problems and subtle inconsistencies that erode the accuracy of advanced analytical methods.
We pay close attention to how labs actually store and use Xylenol Orange. Exposure to air and light can affect long-term stability, leading to faded color or, worse, unwanted chemical change. Amber glass isn’t window dressing for us; it reflects direct experience with stability trials, where alternative packaging led to performance dropoff in real-world storage. We’ve tested a variety of desiccant types and sealing protocols, updating our approach based on measurable shelf life, not just cost. Our goal is for customers to reach the bottom of each container with the same result as their first titration.
Many large purchasers request batch-level documentation, and we provide full characterization data with each shipment. This goes well beyond a basic certificate of analysis; we routinely share impurity scans, spectral overlays, and test results for trace ion presence. During audits or regulatory inspections, this transparency protects our clients and cements long-term partnerships.
Our experience as direct manufacturers extends into environmental responsibility. Efficient synthesis of Xylenol Orange calls for conscious management of solvent use, recovery, and minimization of hazardous waste. We built our facility to recycle over 85% of process water and solvents, reducing offsite disposal and keeping emissions in check. Whether working with local water boards or larger chemical industry consortia, we share best practices and data on minimizing byproduct formation without compromising reagent performance.
Customers appreciate options for bulk packaging, which means fewer small containers and less landfill waste—especially for industrial users moving through kilograms of material each year. We advise on safe reagent disposal and collaborate with larger partners to facilitate on-site reclamation or safe destruction, staying within evolving regulatory and industry standards. These steps aren’t marketing points; they reflect both the demands of our production process and the ethical responsibility of chemical manufacturing in contemporary society.
In busy laboratories, slow or unpredictable response times from reagent suppliers create real bottlenecks. As direct producers, we recognize the urgency and strive to keep customer timelines realistic. If a problem arises—a suspicious endpoint shift, an off-odor, a delay in shipment—our technical and distribution staff investigate at the manufacturing level, often tracing the issue back to a specific batch or production stage.
Feedback loops matter. Product improvement isn’t theoretical in our world; it happens through cycles of listening, diagnostics, and targeted reformulation. After a major analytical lab flagged a reactivity issue last year, we traced the root cause to a supplier-provided solvent not meeting our own revised standards. Instead of blaming upstream sources, we switched purchasing channels and retested with our own in-house protocols. Results improved across all customer endpoints, and we used this case internally to strengthen both training and future batch checks.
Over decades, we’ve built partnerships not by promising more features, but by delivering on the core attributes labs feel every day—reliable performance, clear point-of-contact, and technical expertise directly from a manufacturing foundation. We don’t simply fill demand; we anticipate needs as analytical standards evolve and bring the lessons from thousands of routine titrations back into our workflows.
Whether supporting a water treatment plant, a materials science researcher, or a teaching laboratory, our approach adapts to the realities of each client. Our sales and technical teams speak directly from bench and production experience, grounded in both the chemistry and logistics of reliable analysis, not generic specifications. This direct engagement leads to improvements in formulation, storage recommendations, and support, all delivered with the full resources of a manufacturing operation, not a sales office.
Our production of Xylenol Orange (Reagent Grade) reflects an ongoing commitment to real-world outcomes, not abstract marketing. Every batch represents a synergy of advanced synthesis, practical QC measures, tight logistic controls, and a culture of transparency with end users. Through this process, we help ensure that a vital analytical tool—one that underpins both research and industry testing—remains as reliable and clear as the day it first appeared in our labs.
Quality here comes from experience, continual vigilance, and an open-door approach to partnerships and improvements. As scientists at heart, we share not only a reagent, but a direct link from manufacturing expertise to the technical work of analysts, educators, and industry quality professionals worldwide.