Anhui Liwei Chemical Co., Limited
Products

Phenolphthalein Anilide


    • Product Name Phenolphthalein Anilide
    • Alias N-Phenylphthalamide
    • Einecs 274-861-9
    • Mininmum Order 1 g
    • Factory Site Lingwu, Yinchuan, Ningxia, China
    • Price Inquiry sales2@liwei-chem.com
    • Manufacturer Anhui Liwei Chemical Co., Limited
    • CONTACT NOW
    VTB
    Specifications

    HS Code

    310289

    Cas Number 2097-18-1
    Molecular Formula C27H20N2O2
    Molecular Weight 404.47 g/mol
    Appearance Light yellow to yellow powder
    Melting Point 220-222°C
    Solubility Insoluble in water, soluble in ethanol and acetone
    Purity Typically >98%
    Boiling Point Decomposes before boiling
    Storage Temperature Store below 30°C in a cool, dry place
    Uses Intermediate for dyes and pigments

    As an accredited Phenolphthalein Anilide factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Amber glass bottle containing 25g of Phenolphthalein Anilide; labeled with chemical name, formula, danger warnings, and manufacturer details.
    Shipping Phenolphthalein Anilide should be shipped in tightly sealed containers, protected from moisture and light. Use appropriate hazard labeling as per relevant regulations. Transport in compliance with local and international chemical shipping guidelines, ensuring secondary containment to prevent leaks. Handle carefully to avoid breakage, and include safety data sheets with the shipment.
    Storage Phenolphthalein Anilide should be stored in a tightly closed container, kept in a cool, dry, and well-ventilated area away from incompatible substances such as strong oxidizing agents. Protect the chemical from moisture, direct sunlight, and sources of ignition. Proper labeling, segregation, and adherence to safety data sheet (SDS) recommendations are essential for safe storage and handling.
    Free Quote

    Competitive Phenolphthalein Anilide prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615380400285 or mail to sales2@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615380400285

    Email: sales2@liwei-chem.com

    Get Free Quote of Anhui Liwei Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Phenolphthalein Anilide: Precision and Clarity for Analytical Chemistry

    Introducing Our Phenolphthalein Anilide

    For nearly three decades, our team has kept a close eye on the shifting expectations of laboratories and industrial chemists. Through constant refinement, our Phenolphthalein Anilide sets a high standard in analytical chemistry, delivering purity and dependability batch after batch. Unlike many other indicators or specialty reagents, we blend years of technical experience with a practical understanding of what matters on the production floor and at the lab bench.

    Phenolphthalein Anilide comes packed in airtight containers to preserve integrity. Our standard product features a purity above 99.2%, after drying, measured using industry-accepted titration and chromatographic methods. The off-white to pale pink powder granulates well without aggregation, flows cleanly, and leaves no sticky residue on scoops or spatulas. Each production lot meets strict quality checkpoints for melting range (260-265°C), solubility in common laboratory solvents, and low impurity thresholds. Years of careful process improvements have helped us trim trace byproducts to below detection, ensuring your analyses don’t suffer interference.

    Why We Developed This Product

    The need to sharpen endpoint detection pushed us toward Phenolphthalein Anilide early on. Too often, analysts struggled with ambiguous color changes or inconsistent titration curves when using older phenolphthalein derivatives or mixtures. We took feedback from both academic and process chemists, then optimized our process to address these frustrations. The result is a compound with crisp, reliable performance across a wide pH range, supporting both educational demonstration work and industrial monitoring.

    By focusing R&D time on temperature stability, we reduced the problem of fading or drifting hues in extended titrations. This lets labs work with confidence during slow transitions—whether scaling up detergents, assessing water hardness, or monitoring basicity in chemical reactions. Years ago, one customer described how our anilide held color in strong base for over two hours without a hint of yellowing or decomposition—a big leap from previous products that tired out in under thirty minutes.

    Comparison to Traditional Phenolphthalein and Alternatives

    Phenolphthalein Anilide stands apart from plain phenolphthalein in several key ways. While the base compound quickly cycles from colorless to pink between pH 8.2 and 10, the anilide form draws a noticeably sharper line, minimizing transitional fuzziness around endpoints. Academic instructors often report a lower rate of student titration errors when switching to our product. For titrations requiring multi-point detection or more protracted run times, the anilide’s resilience against photodegradation reduces the chance of early color loss.

    Another difference appears in solubility and dissolution speed. Compared to methyl orange, bromothymol blue, or thymolphthalein, our Phenolphthalein Anilide dissolves steadily and resists clumping. We fine-tune the grinding step for optimal particle size, so you get rapid, homogenous color dispersion without pockets of undissolved solid. This matters in both automated analyzers and traditional glassware setups, where delayed or uneven mixing can create confusion and extra rework.

    With competitors, purity often comes at the cost of shelf life. By narrowing the recrystallization window, we keep residual solvents below 0.01%, which means no sticky hands or crystalline dust plumes during weighing. Packages stored at ordinary room temperature have exceeded five years without detectable decomposition or moisture pickup. Our customers in food and water testing labs frequently cite this extended stability as a crucial advantage, especially in remote regions or climates prone to seasonal humidity swings.

    Lab and Field Usage

    Our main customers use Phenolphthalein Anilide in neutralization titrations, especially in situations where accuracy deeply affects costs. In regulated wastewater and drinking water facilities, even a tenth of a pH unit off the mark can mean regulatory fines or expensive process reruns. By giving analysts a strong, unambiguous read on the endpoint, false positives and the need for retesting drop off. In one example from our records, a textile plant using our product cut titrant waste by sixteen percent after switching, simply by slashing the number of retitrations caused by indistinct color changes.

    Academic departments rely on our material in both research and classroom demonstrations. It gives students instant visual feedback during acid-base experiments and holds up to repeated heating and mixing. Educational purchases typically require lots in the hundred-gram to kilogram scale; our in-house packing line speeds delivery, preventing bottlenecks during semester startups. Unlike cheaper imports suffering from variable performance, our lots stay internally consistent across academic cycles, which faculty report reduces lesson planning headaches.

    Oilfield chemists and environmental analysts develop titration methods requiring more nuanced color shifts. For them, Phenolphthalein Anilide fits applications that standard indicators fail to cover. Routine analysis of formation water, oil-in-water separation, or scaling potential often confronts harsh, interfering sample matrices—chlorides, sulfates, and even some dispersed oils. Our customers in these fields consistently tell us our product’s high threshold for interference avoids false endpoints, keeps data clean, and reduces the frequency of backup testing by five to ten percent.

    Quality Commitment—What Sets Us Apart

    We stay involved in every batch—from raw material screening through final drum filling. Workers at our facility know the stakes in analytical chemistry; a small slip in batch consistency can skew a project, disrupt a plant, or send the wrong results to government auditors. Our lab technicians double-check each production run with independent identity and purity assays using NMR and HPLC. Certificates of Analysis come with full documentation of analytical protocols and calibration standards used, not just checkboxes or perfunctory signatures.

    Sometimes a partner’s method development throws us curveballs: requests for larger particle sizes to fit non-standard instrumentation, an extra wash step to remove a trace impurity, or customized packaging to fit automated liquid dispensers. With an R&D department physically attached to our plant, feedback moves quickly to practical resolution. Our lead chemist, who has overseen thousands of batches, still spots issues by smell, feel, or the way a powder moves across a tray—human experience that can't be replaced by software alerts or remote contractors.

    We invite regular third-party audits. These cover not just product samples but also operator training logs, cleaning records, and process equipment maintenance. Several global partners have run verification tests, confirming our specifications hold up not just on paper, but in real-world lab and process environments. Our main plant operates under strict cGMP and ISO procedures, but we go further—logging anomalies as small as temperature spikes or unusual noise from motors, then tracking these in our process control system. Each mistake or near-miss builds a stronger foundation for the next lot.

    Real-World Problems and Practical Solutions

    Market volatility and rising raw material costs sometimes squeeze specialty chemical supply chains, leading to cut corners in production or inconsistent batches from outside vendors. We saw several waves of this during recent global supply disruptions. In response, we doubled down on long-term purchase agreements with main upstream suppliers. By investing in redundant purification lines and larger on-site storage capacity, we keep producing high purity Phenolphthalein Anilide even when many competitors ration supply or hike prices.

    Another pain point involves the trade-off between reagent purity and field robustness. Some users accept lower purity to save costs, but encounter drift or more frequent recalibration in use. Others buy “high purity” grades, but find hidden contaminants sabotage important experiments. Our philosophy draws on practical experience: the money saved on lower purity is quickly lost once failed analyses, regulatory visits, or missed project deadlines pile up. For this reason, we put extra muscle into batch screening and raw material qualification, preferring to reject questionable lots rather than risk unhappy repeat customers.

    Shipping and storage problems caused by temperature swings challenged us in certain climates. Deliveries to remote Africa, South Asia, and Australia sometimes faced warehouse stops with poor climate control. A few years back, a bulk user in Indonesia reported caking in product from a different manufacturer after sea transit. Our technical team collaborated with their purchasing agents to test different container linings and desiccant choices, finally settling on the current blown-polymer barrier that keeps moisture ingress below one percent, even in 40°C heat and 90% relative humidity. Returned product rates linked to shipping stress dropped seventy percent since this upgrade.

    Supporting Labs and Industries—Our Ongoing Mission

    Years of listening to feedback shape each batch and lot we deliver. Colleges need tight control over what students experience in chemistry labs. Plant operators demand reliability over long production shifts. Environmental labs can’t afford guesswork when running hundreds of titrations per week to protect water sources. That’s why every step of our process, from weighing the first kilogram of raw feedstock to closing the last drum, rests on practical expertise.

    Because we manufacture, not just repackage or broker shipments, we know exactly how each step in synthesis and purification affects performance. Many distributors source from a rotating cast of overseas suppliers, leading to surprises in particle size, color response, and expiration dates. By staying in control, we keep specifications meaningful—and we answer directly for any question, complaint, or special technical requirement.

    We also recognize the growing call for sustainable and safer production practices. While Phenolphthalein Anilide itself poses low direct risk when handled responsibly, our plant replaced chlorinated solvents and switched to closed-loop washing years before regulators demanded such changes. This upgrade not only cut air emissions, but also slashed process water waste by nearly forty percent. Customers won’t see the difference at the lab bench, but that unseen progress keeps both communities and regulators confident about working with our team.

    Key Differences—Detail by Detail

    One chemical's label can look like another, but attention to detail separates commodities from precision tools. In the case of Phenolphthalein Anilide, our experience taught us four crucial differences from competitors:

    User Experience—Working Chemist Insights

    We lean on the trust that comes from years of back-and-forth with professional users. A university instructor in Central Europe recently described fewer missed endpoints in freshmen classes, cutting failure rates by nearly a third. Staff working in chemical process plants pointed to reduced downtime, as the anilide’s extended shelf-life meant fewer mid-year material changes and less paperwork. Environmental officers relying on our indicator for large-scale water testing tell us that unambiguous endpoints let them confidently clear hundreds of samples daily, without second-guessing results or dipping back into control stocks between test runs.

    Our open-door policy means that when customers spot something unexpected—snowy clumping during winter delivery, a melting range shift due to new glassware, or batch-to-batch color variance—our production chemists troubleshoot directly. We have solved everything from unexpected glass etching due to accidental acidic exposure, to questions on how to handle trace carry-over between titration series. Experience tells us these hands-on details matter more than glossy brochures or standard claims.

    Given the complexity of many sample types, laboratories face continual pressure to adapt protocols while keeping accuracy. We often help partners validate or optimize methods for emerging contaminants, industrial wastes, or specialty process needs—all using our Phenolphthalein Anilide as a dependable endpoint marker. Field use frequently throws up less-than-ideal conditions (high particulate loads, variable temperatures, power outages). Our technical service group tracks these cases for internal review—every real-world report guides future improvements.

    Ongoing Research and Adaptation

    Our work does not end once a lot leaves the warehouse. Continuous sampling and method revision drive incremental improvements, not only to meet compliance, but to stay ahead of new analytical demands. Over the years, customer requests led us to test alternative pack sizes, deliver microbatches for high-throughput robotic installations, and develop specialized blends for unique industry requirements. Our R&D pipeline currently investigates next-generation derivatives with even sharper transition points and greater compatibility with trace anion analysis.

    Feedback channels remain open. We invite direct communication on custom formulations, compatibility with emerging assay technologies, and real-world sampling conditions that stress-test the product. Whether your team works in remote field stations or gleaming city laboratories, our decades of process and application know-how—and our willingness to adapt—set us apart from those who just move chemicals from point A to point B.

    Practical Points for Decision Makers

    Procurement managers and technical leads value more than price per gram. Supplies that look interchangeable often perform worlds apart once in the lab or plant. Our approach grounds product value squarely in reducing the “total cost of use”—fewer failed tests, less labor time chasing ambiguity, lowered documentation headaches, and real-world savings over years, not just quarters.

    For labs considering whether to switch to Phenolphthalein Anilide, we offer both technical consultation and sample evaluation. Our support doesn’t come from detached sales teams but from people who run the production lines, solve contamination puzzles, and understand the view from both bench and management. Decisions in chemistry ripple outward: smarter, more capable indicators help streamline larger workflows and support regulatory confidence.

    Conclusion—Our Continuing Commitment

    Phenolphthalein Anilide represents not just another product, but the result of years of relentless improvement, direct user input, and dedicated chemical manufacturing. Each batch reflects our commitment to clarity, reliability, and practical support for working chemists across fields. For those who seek confidence in their analytical results and a partner invested in long-term success, our product—and the experience behind it—stands ready.