|
HS Code |
340746 |
| Product Name | Phenol Water Saturated Solution, Dnase, Rnase, Protease Free, Stab. |
| Physical State | Liquid |
| Appearance | Clear to slightly yellow |
| Ph | approx. 6.6-7.9 |
| Solubility | Completely miscible with water |
| Storage Temperature | 2-8°C |
| Application | Nucleic acid extraction and purification |
| Hazard Classification | Toxic, Corrosive |
| Molecular Formula | C6H5OH (Phenol component) |
| Boiling Point | about 182°C (phenol) |
| Density | 1.06 g/cm³ (approximate) |
| Cas Number | 108-95-2 (phenol) |
As an accredited Phenol Water Saturated Solution,Dnase,Rnase,Protease Free,Stab. factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Clear, amber glass bottle, 100 mL, screw cap, tamper-evident seal; labeled “Phenol Water Saturated Solution, DNase/RNase/Protease Free, Stabilized.” |
| Shipping | Phenol Water Saturated Solution, DNase, RNase, Protease Free, Stab. is shipped in secure, leak-proof containers with appropriate chemical hazard labeling. It is packed according to regulatory standards for hazardous materials, often with cold packs or insulation to maintain stability during transit and ensure the integrity and safety of the reagent upon arrival. |
| Storage | Store **Phenol Water Saturated Solution, DNase, RNase, Protease Free, Stabilized** at 2–8°C, protected from light in a tightly sealed container. Keep away from heat, sources of ignition, and incompatible materials. Use in a well-ventilated area, wearing appropriate personal protective equipment. Ensure the solution remains stabilized and uncontaminated for reliable nucleic acid extraction or purification applications. |
Competitive Phenol Water Saturated Solution,Dnase,Rnase,Protease Free,Stab. prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615380400285 or mail to sales2@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8615380400285
Email: sales2@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Our journey in the field of chemical manufacturing started decades ago with the clear recognition that innovation alone does not sustain progress—careful attention to process detail, raw material selection, and vigilant purity controls do. In contexts where researchers demand uncompromising performance from every reagent, we have often seen the cost and frustration that come with contaminated chemicals. This experience motivated us to produce the Phenol Water Saturated Solution, DNase, RNase, Protease Free, Stab., specifically for molecular biology applications where enzyme contamination is simply not tolerable.
Phenol routinely serves as an essential reagent during the extraction of nucleic acids, and this places special burdens on its purity. Even microgram quantities of nucleases or proteases can alter the outcome of a critical PCR, degrade a precious RNA sample, or impede sequencing fidelity. At our plant, raw phenol does not get the fast lane treatment. We maintain dedicated systems and process lines, not shared with less stringent materials, so cross-contamination is avoided. Our phenol undergoes thorough purification and water saturation via partitioning with high-purity water—this stabilizes the reagent, minimizes oxidation, and ensures that no residual enzyme activity lurks within the final batch.
Through every batch run, we test for and eliminate traces of DNase, RNase, and protease. It is not enough to accept certificates from suppliers or lean on third-party validation. Every drum and bottle leaving our site bears a test record that aligns with in-house analytical documentation, built on both in-line and end-product testing. We follow stringent, industry-accepted protocols for enzyme detection, including highly sensitive fluorometric and gel-based assays, because scientists downstream don't need another source of variable data. We have invested in isolating all manufacturing environments. Any technician transferring material into storage vessels adheres to strict PPE guidelines and works under controlled-air conditions, limiting airborne microbial or enzymatic risk.
Aqueous phenol, unlike dry phenol, presents extra challenges in storage and usage. Phenol has hydroscopic properties—attracting and retaining water from its environment. This property, long familiar to chemists who have handled solidified phenol or had to re-dissolve crusted reagent, translates to nuances in preparation. Our methodology ensures the solution is thoroughly water-saturated prior to bottling, with no phase separation or instability. This is critical because phenol rapidly oxidizes when there's exposure to air or inadequate water content. Such oxidized forms can seriously interfere with downstream applications, sometimes introducing byproducts that compromise the integrity of nucleic acid extractions or protein denaturation procedures.
Several times, scientists have described poor phenol extractions owing to a lack of attention to the water saturation step. On the manufacturing side, we've found that skipping or rushing this step leads to inconsistent product, unpredictable pH shifts, or stratification in cold storage. All of these can negatively impact extraction yields and subsequent analyses. By maintaining stable water saturation, we effectively minimize batch-to-batch variability—a practical benefit our long-term institutional clients have come to rely on.
Lab workers and researchers face enough challenges without worrying about shrinking shelf lives and surprise discolorations. Oxidation remains the major threat to both phenol and the success of nucleic acid work. As a manufacturer, we have seen how even trace levels of peroxides formed in phenol storage change reaction outcomes. Our Stab. (stabilized) version includes trusted antioxidants, absent any contaminants that interfere with nucleic acid extractions or RNA handling. Over the years, we adjusted antioxidant concentration and type based on both internal aging studies and real feedback from active research labs.
We also carefully select glass and cap linings that do not leach any extractables into the phenol. Polypropylene and polyethylene capping materials underwent compatibility and migration testing. More than once, after launches of new bottle shipments, we discovered leaching or interaction issues in stability tests and, from that point forward, began approving packaging in partnership with laboratory end users. Our stabilization protocol avoids the sharp, pink-purple colors that serve as early warning signs of oxidation, ensuring a clear, colorless or faintly yellow solution on receipt and throughout documented storage times.
Researchers working with RNA understand how unforgiving even minor RNase contamination can be. RNA is especially prone to rapid degradation; irretrievable sample loss is all too common even with minute enzyme presence. DNA extractions see similar threats from lingering DNase, whether introduced during production or, as happens in some facilities, through recycled glassware or non-segregated processing. Protein biochemistry struggles with proteases which cleave target proteins before purification. Every one of these situations justifies our focus on triple-negative enzyme status.
We guarantee this phenotype by keeping all equipment dedicated: cleaning protocols, validated with in-house controls, use high-concentration base and acid washes, followed by depyrogenized water rinses—never tap supply, always ultrapure. Employees receive recurrent training specific to nuclease risk and the unique handling requirements of reagents for molecular biology. Teams periodically rotate through roles so that procedural discipline does not degrade, and anyone who spots a process anomaly raises it for immediate review, no matter their level. These institutional habits help us avoid the kinds of contamination events that have shut down production lines in companies focused only on throughput.
We routinely meet researchers who have struggled with off-the-shelf technical-grade phenol. Outside the molecular biology field, the needs differ: minor contaminants, colored solutions, or uncertain water content don’t matter for simple chemical synthesis or low-end QC. In the research world, this doesn't fly. Store-bought phenol often carries stabilizers such as 8-hydroxyquinoline, designed for long chemical shelf life, but these introduce interfering activities into molecular protocols. Our solution, by contrast, forgoes stabilizers that bind, degrade, or mask nucleic acids.
The model we ship for molecular purposes draws its main distinction through absolute absence of DNase, RNase, and protease, with added stabilization that does not cross-react or add background signals. Researchers working on GC-rich or methylated DNA, sRNA, or highly labile transcriptome projects have shown us how off-the-shelf material triggers false negatives or sample failures. Our phenol solution always undergoes full batch testing, including actual extraction pilot runs, to verify that downstream clarity and recovery remain uncompromised. End users have traced failed RNA-Seq runs to supplier-grade switches—underscoring that seemingly subtle differences in chemical prep lead to disproportionate downstream cost and lost work.
Our water saturated, DNase/RNase/Protease free, stabilized phenol solution helps support the full arc of typical downstream applications: DNA extraction with high purity, phenol-chloroform methods for RNA, and workflows in protein denaturation or immunoprecipitation. We design our specifications with those end points in mind, drawing from thousands of production runs and continual dialogue with bench scientists who share their pain points.
Phenol’s chemical structure and volatility generate complicated behavior through storage, especially above room temperature or in high humidity. Many facilities suffer phenol crystallization during cool seasons, or discover sludging in older bottles. We run monthly simulation tests in varied temperature and humidity chambers, constantly learning what does and does not threaten our clients’ success. Our bottles ship in dark, light-blocking packaging. Labels list full bottling, lot, and minimum storage information—not only for traceability but as a practical record for researchers who may keep a reagent halfway through its rated shelf life.
Through repetition, we have found that honest storage data means fewer client complaints and far fewer urgent “rescue calls” from users facing panic in the middle of a grant-critical workflow. Bottles are filled in nitrogen or argon-flushed environments to drive off oxygen, and sealed immediately upon fill, so slow oxidation is kept at bay. Each storage test comes with a paired analytical outcome being logged and shared with our regular client base on request. We have learned, sometimes painfully, that few things are more frustrating to researchers than discovering unannounced changes in handling recommendations or unexplained differences in performance batch-to-batch. Consistency breeds trust, and our attention to stability protects our own operation’s reputation as much as it protects a researcher’s next experiment.
Across the years, talking with technicians and postdocs who struggle with “dead” extractions (no visible nucleic acid, unexplained smears), we have found that reagent choice often sits at the center of their frustration. Teams using our phenol repeatedly share details about cleaner DNA bands, improved RNA yields, and downstream PCRs that generate fewer artifacts. More important to us than isolated testimonials are long-running purchasing partnerships from major universities and research hospitals. Several clients submit blinded evaluations, comparing extractions run side-by-side with ours and “the standard” technical-grade phenol. The differences—sometimes visible as clean bands versus ghost smears—reaffirm the reason we invest in continual process improvement.
Young laboratories often come to us after bad experiences with imports from traders or generic bulk resellers. These labs report bottle-to-bottle inconsistencies, pronounced odors (from byproducts or stabilizer breakdown), and unpredictable shelf life. Our own view, influenced by handling our own repairs of failed extractions, is that many of these pain points are avoidable if the manufacturer maintains robust inbound testing, segregated process lines, and honest batch disclosure. We regularly solicit feedback from our regulars—and, in the few cases when an issue arises, we review, reproduce, and respond swiftly. A lost sample can mean the loss of six months' work for a researcher; chemical manufacturing, in this context, has direct ethical responsibility to protect both investment and knowledge progress.
All lab chemicals come with risk, and phenol is no exception. We go beyond minimum safety regulations in both internal training and our communications with users. We share our standard operating procedures for safe handling—not simply “read the SDS and follow instructions.” Practical experience has taught us that good ventilation, effective eye and skin protection, and using only borosilicate glassware (never polystyrene, which phenol attacks) make a bigger difference than reams of paperwork. Our safety teams routinely test our recommendations against real-world lab audits from our top clients. This ongoing feedback loop means what we advise matches the realities of small, crowded university labs, not just theoretical safety statements.
Many research users focus on minimizing vapor exposure and keeping phenol away from acids or bases, which can trigger dangerous reactions or outgassing. Storage at 2-8°C, in darkness, prevents breakdown and preserves performance. We’ve seen the damage that comes from improper storage: yellowed solutions filled with polymerized byproducts, crusted caps, or bottles that “weep” stains onto shelves. We designed our shipment boxes not just for in-transit safety but to be reused as long-term storage secondaries, helping avoid accidental exposure incidents that can cause injury, lost time, or worse.
Manufacturing reagents for molecular biology is not a business for the careless or the risk-tolerant. Generic suppliers, white-label traders, and bulk gray-market sources have shaken both client trust and reproducibility in life science research. We regularly hear from researchers who ended up with batches displaying spontaneous color changes, unpredictable pH drift, or even carryover of previous batch contaminants. These stories inform our core values around traceability, open communication, and batch record retention. Our team runs a full review of incoming chemical shipments, evaluating COAs and running own multi-point purity and sterility tests. Each manufacturing run logs who handled what, where, and when, cross-linking production to finished product bottling.
Experience shows that reliable reagents drive clearer science and more reliable outcomes. Chemists, molecular biologists, and clinical researchers have openly shared the difficulties of irreproducible extractions stemming from “invisible” variables—a phenol batch that sits on the dock for too long, absorbing ambient humidity, or a plastic cap liner introducing previously untested substances. By maintaining direct control over sourcing, processing, and packaging, we keep those variables visible, tracked, and within acceptable range.
Over the past decade, the scientific community has intensified focus on reproducibility in experimental research. Large meta-analyses have revealed unacceptably high rates of irreproducibility, with contaminated or inconsistent reagents ranking among the recurring culprits. As a manufacturer directly supplying to research institutions, we treat every outgoing bottle as a contributor—or a possible risk—to a global research project. Any chemical batch that fails to support consistent experimental results represents not just financial loss, but setbacks in trusted discoveries and scientific progress. Our responsibility, rooted in years of hands-on production, is to keep contamination and variability out of our customers' projects.
Quality assurance means more than certificates and lot numbers. Our team regularly reviews literature—sometimes tracking feedback from public research projects that mention failed nucleic acid procedures—and routinely upgrades our analytical capabilities in line with emerging enzyme detection technology. We maintain a standing invitation for site visits, audits, and method sharing with partner research centers, so transparency supports trust.
Chemistry in the service of biology does not tolerate shortcuts. Over the years, our team has seen cycles of supplier volatility, raw material shortages, and market entry of cheaper, inferior products. These trends threaten the fragile pipeline of innovation that relies on reliable, clean, optimized reagents. Our solutions, including the Phenol Water Saturated Solution, DNase, RNase, Protease Free, Stab., support scientists at all stages—from undergraduate researchers learning extraction basics to senior investigators leading multimillion-dollar consortia.
In a climate where grant timelines, publishing expectations, and stakeholder scrutiny all press harder, manufacturing integrity stands as one of the few variables in scientific research that can be directly controlled. We do not introduce unnecessary stabilizers or cost-saving substitutions. Each protocol change, even at the milligram scale, is validated, documented, and shared with end users. We have learned to refuse requests to “speed up” lots at the expense of testing, even under supply pressure.
As we look toward continuous improvement, our internal technical committees draw on collaborative relationships with research users. We engage directly with lab managers and frontline scientists, attending to extraction failures, pH drifts, and unexpected bands. Our phenol solution is shaped as much by what happens in those labs as by our process data. A good proportion of new product tweaks trace back to a single conference call or benchside observation, not management edict.
Trust in a manufacturer grows one successful project at a time. We take pride in supporting researchers’ efforts at the frontier—whether exploring transcriptomics, proteomics, or new diagnostic workflows. Our dedication to clean, stable, and predictable chemicals does not reflect a marketing slogan, but a set of habits and values formed through listening and responding to the growing needs of molecular biology researchers around the world.
Every year brings new demands, evolving standards, and surprise challenges in molecular biology and chemistry. Through all of this, our core principle persists: no batch ships without full confidence in purity, stability, and suitability. Phenol Water Saturated Solution, DNase, RNase, Protease Free, Stab. represents not just a reagent, but the result of sustained attention to process integrity and real-world researcher outcomes. Each lot we produce stands as our answer to the very real need for reproducible, contamination-free, shelf-stable solutions. It is a product that, through years of ongoing refinement and user feedback, genuinely supports the global effort to produce reliable, publishable science.