HS Code |
684923 |
| Cas Number | 887586-61-8 |
| Molecular Formula | C6H3BrFNO3 |
| Molecular Weight | 236.99 |
| Appearance | Yellow solid |
| Melting Point | 140-143°C |
| Purity | Typically ≥98% |
| Solubility | Slightly soluble in water; soluble in organic solvents |
| Synonyms | 4-Bromo-2-fluoro-6-nitro-1-phenol |
| Smiles | C1=C(C=C(C(=C1O)[N+](=O)[O-])Br)F |
| Inchi | InChI=1S/C6H3BrFNO3/c7-3-1-4(8)6(10(12)13)2-5(3)9/h1-2,9H |
As an accredited 4-Bromo-2-Fluoro-6-Nitrophenol factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Amber glass bottle, tightly sealed, labeled with hazard symbols; contains 10 grams of 4-Bromo-2-Fluoro-6-Nitrophenol powder. |
| Shipping | 4-Bromo-2-Fluoro-6-Nitrophenol ships in tightly sealed, chemically resistant containers. It should be handled as a hazardous chemical, with care to avoid exposure. Shipping complies with international regulations for dangerous goods, utilizing appropriate labeling and protection against moisture, light, and breakage during transit to ensure safe delivery. |
| Storage | 4-Bromo-2-Fluoro-6-Nitrophenol should be stored in a tightly sealed container, away from light, moisture, and incompatible materials (such as strong bases or reducing agents). Keep in a cool, dry, and well-ventilated area, ideally in a designated chemical storage cabinet. Ensure proper chemical labeling and restrict access to qualified personnel familiar with safe handling procedures. |
Competitive 4-Bromo-2-Fluoro-6-Nitrophenol prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615380400285 or mail to sales2@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8615380400285
Email: sales2@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
We make 4-Bromo-2-Fluoro-6-Nitrophenol for chemists who demand reproducibility and reliable material for synthesis. Our shop floors don’t run on assumptions or shortcuts. Every batch comes from honest, scrupulous work in temperature-controlled reactors where impurities don’t get to hide. This isn’t just an organic intermediate to us—it’s a representation of months dialing in process parameters, calibrations, filtration protocols, and clean-in-place cycles with a dedicated team breathing the air of our own cleanup grade.
This compound shows off a molecular formula of C6H3BrFNO3. Its structure—compact, distinctive, and charged with possibilities—features a bromo, fluoro, and nitro group arranged on a phenolic ring. We see this as a lively intersection of reactivity for people building more complex molecules. Every drum, kilo, and vial represents a tangible part of our work life. We recognize the sharpness of its melting point (typically 114–117°C), the subtle yellow hue under warehouse lights, the almost biting sharpness of its aroma in the cleanrooms. We track water content, ash, and identify trace levels using GC and HPLC. Our minds rarely drift during analysis because even a fraction of impurity brings trouble in the process downstream.
Every tag that reads "direct from the manufacturer" means we’re not moving someone else’s product. We know the upstream raw materials by batch code, fingerprint solvent carryovers, and catch rogue byproducts before they become headaches for a customer. Distributors may promise availability; we show it by tightening up our planning and maintaining supply chains even when upstream halts put spot prices through the roof.
This product isn’t about filling catalogs with similar names and hoping anyone will buy. Our focus lands on technical buyers: the route developers in API labs, the medchem groups who need a phenolic group to anchor a Suzuki coupling, the custom peptide people stacking aromatic blocks, or pigment innovators tuning colorfastness with halogenated substitutions. Consistent quality allows them to run parallel experiments, scale up with fewer surprises, and avoid sitting on held-up projects when another lot acts up.
From our windows we see two kinds of customers. One group brings us their challenge—make a clean intermediate, hit a specification, or catch a particular impurity. The other group calls us because last year’s compound failed reproducibility tests at scale. This nitrophenol stands out because the bromine and fluorine create a capable handle for halogen-lithium exchange, cross-coupling, or targeted substitution reactions. Even a small difference in ortho versus para positioning throws off reactivity, so accuracy in regioselective synthesis is not negotiable.
We’ve sent this compound into projects where fluorine improves metabolic stability in active pharma ingredients, or where the nitro group modifies electron density for later reduction and amination steps. Painstaking separation of positional isomers, reduction of colored tars, and control over water content have all proved essential for our clients’ trials and regulatory filings. This is also an anchor for route scouting—a way to insert desired aryl blocks midway through a synthetic sequence, bypassing longer linear routes and lowering total waste.
People new to this market sometimes group all specialty nitrophenols together and focus on price per kilo. Our plant managers know the catch: poorly controlled halogenation or nitration leaves unambiguous footprints that frustrate downstream users. Excessive darkening, sticky residues, or trace chlorides each turn a so-called “good price” into a technical complaint. Direct manufacturers like us can react; we investigate sources of microcontamination, swap out an inconsistent solvent lot, or fine-tune temperature profiles. Our operators see themselves as stewards of traceability—the people who remember which reactor liner performed best for small-scale batches, or which atmospheric venting cut discoloration rates in half.
We routinely send out full trace impurity breakdowns and memories of a time a customer flagged a single HPLC peak that showed up only at 0.2%. We tore apart our own procedures and replaced a problematic phase separator to keep the compound clean. This hands-on control allows an end user to take on our material at the bench or pilot reactor and start using it immediately.
Measurable metrics justify trust. We deliver 4-Bromo-2-Fluoro-6-Nitrophenol with assay levels above 98% by HPLC, ash within control, water content lower than 0.5%. Our in-house analytical chemists can spot signals of hydrolyzed byproducts or O-alkylated impurities quickly. Shelf life isn’t theoretical; we track ongoing stability by periodically re-sampling retained lots that have aged. Customers who calibrate to their own GC, IR, or mass specs appreciate a dose of openness—if the melting point is two degrees lower than usual, they know we’ve already traced the variable.
Materials stored in our monitored warehouses don’t undergo random temperature fluctuations. With each repeat order, the product matches the previous lot’s fingerprint. We’ve invested in nitrogen blanketing, robust packaging, and batch-level certificates tailored for each delivery. A photo ionization detector isn’t a luxury here; it’s daily assurance for the integrity of lightly volatile fractions. This level of vigilance means integrations into pharmaceutical, agrochemical, or specialty pigment syntheses happen without unnecessary stops.
Running a chemical plant isn’t a clinical exercise. We learn hard lessons from human error and the odd rogue spark. During our early years, a single misreading on the bromine feed or a ten-minute delay on quench provided a ton of material with off-spec properties. We teach each new operator the texture and stickiness of the raw phenol, the way a certain yellow hue signals the right nitro level, and how trace tan coloring points to unavoidable over-nitration.
Distributors without a plant don’t see what happens behind these walls—the repeated cleaning, pressure testing, and sometimes draining a $40,000 batch because it just didn’t smell right. Our staff debates the best rinsing method for glassware; we talk through whether to override standard filtration time if the cake pressure spikes. Some days, a five-degree offset on the jacket heat means we catch escape peaks on GC that would have tripped up a multi-million dollar downstream trial.
Our choice to control every step hasn’t come cheap, but it puts us in a position to adapt. If a new regulatory restriction hits on an impurity class, we aren’t waiting months for an upstream fix—we’re tracking and adjusting from the reactor base upwards.
Put two samples of the same compound side by side—one from a trading route and one from our direct process. The external difference may be indistinguishable, but run the same Suzuki, Buchwald, or amination, and disparities show up. Our in-house teams know which analytical signatures to expect and train new analysts to catch subtle drift from reference spectra.
Batch-to-batch consistency is seen less as a statistical notion and more as a daily necessity. A lab-scale chemist designing for clinical trial thresholds won’t welcome a surprise persistent impurity. Consistency means the same vial behaves in every coupling, esterification, or reduction from milligrams to multiple kilograms. That’s not something achieved by luck, but by thousands of cumulative hours on the plant floor.
Some of our favorite improvements originate with customers who need a purer route or a capped impurity. An R&D lab specializing in oncology flagged a pattern in side reactions and asked for a custom drying regime. We experimented, tweaked the rotary evaporator setup, and landed at a better residual solvent specification. Now, their lot variability dropped, and they’re the reference for another division.
Regulatory affairs staff send us back stability data after accelerated aging, keeping us on our toes with additional stress tests. Our favorite feedback comes from those who think like us—seeking out the roots of each analytical anomaly, not stopping at “within limits.” Direct dialogue trumps templated certificates; it feeds iterative improvements into our daily manufacturing decisions.
A specialty nitrophenol isn’t just a molecule in a bottle. Bromination and nitration on a commercial scale require constant care. The hazards are real, whether it’s handling aggressive intermediates, keeping operator exposure at zero, or neutralizing the waste stream before it leaves our site. We built robust air handling, sealed transfer systems, and triple scrubbers into our daily plant operations. Our operators receive regular health checks, PPE upgrades, and process safety refreshers.
Waste minimization and efficient neutralization go beyond sloganeering. Every liter of spent acid and every filter cake is logged, analyzed, and sent to a certified processor. Colored effluents, once unavoidable, now move through multi-stage oxidation and carbon filtering. We don’t declare environmental compliance as something “achieved”; we treat it as a moving target for which we carry everyday responsibility.
We often get requests comparing this compound with other substituted nitrophenols, like 4-Bromo-2-Chloro-6-Nitrophenol or 2-Fluoro-4-Nitrophenol. Our experience shows these analogues behave differently during key stages. Substituted fluorine at position two brings potent electron-withdrawing effects, influencing reactivity in cross-coupling and nucleophilic aromatic substitution. Bromine at position four, bulky and more polarizable than chlorine, affects solubility, spectral characteristics, and subsequent downstream derivatizations. Our process control ensures that each molecule remains pure to its desired configuration without isomeric crossover, which can otherwise derail synthetic steps or skew analytical profiles.
People focusing on structure-activity relationships in pharma or agrochem need faithful adherence to the specified substitution scheme. Other vendors who juggle multiple compounds on shared lines sometimes end up with unwanted mixed isomers or cross-contaminated batches. Our strict segregation between different halogenations, our careful intermediate purges, and dedicated warehousing keep our product line clean.
Our team understands that real customer trust comes from avoided mistakes: averted delays, unexpected darkening at the plant, fast repeat orders during research sprints, and personal care in fixing a shipment gone wrong. We track every drum from raw material reception through to finished packing with digital traceability, and we keep retention samples for every lot. Private feedback sessions with key customers have fundamentally changed how we run packaging, documentation, and even how we prioritize new investments.
Some discover the value of direct discussion with real chemists only after a problem hits. But those who work with us regularly know their questions won’t get bounced to a faceless help desk. They’ll talk to the people who can pull a batch from the shelf, check the actual GC trace, and suggest how to adjust their next run for a new impurity. This is the lived difference between a plant-driven operation and somebody selling from a spreadsheet.
We don’t stop at delivery. Methods for dissolving, handling, and integrating 4-Bromo-2-Fluoro-6-Nitrophenol aren’t theoretical in our shop. Our technical support teams come from the same labs where we make the stuff. We have trouble-shooted solubility in nonpolar solvents, advised on filtration to avoid losing yield on sticky nitrophenols, and even helped set up GLP-compatible workflows for regulated synthesis. These aren’t sidelines—this is core work, every week.
Our feedback culture turns into an ongoing back-and-forth—what solvents give peak solubility, what packaging makes transfer simplest, how to manage bench toxicity, what to expect from long-term storage, and how to minimize product loss during scale up. These details matter when margins are razor-thin and deadlines non-negotiable.
Technology keeps shifting. Analytical gear updates, regulatory languages change, supply chain shocks grow. Yet through all of this, direct manufacturing keeps us honest. We see every step, every drum, every spec. We can answer why that GC peak moved or how we identified the anomaly in a given lot. Our technical teams, production staff, and QC analysts don’t hide behind layers of intermediaries. Each of us—on the line, in the lab, on logistics—treats this molecule like a demanding relative.
If you work with us, you get more than a CAS number and an invoice. You get a material made for experiments that matter. It’s not about “offering a solution”—it’s about rolling up sleeves and being the people our customers call when they hit a problem, need a tweak in a process, or just want to know what’s actually in their bottle. That’s real manufacturing, every run, every day.