|
HS Code |
844625 |
| Iupac Name | 2,6-Dimethyl-4-iodophenol |
| Molecular Formula | C8H9IO |
| Molecular Weight | 248.06 g/mol |
| Cas Number | 66346-01-8 |
| Appearance | White to off-white solid |
| Melting Point | 112-114°C |
| Purity | Typically ≥98% |
| Solubility | Slightly soluble in water; soluble in organic solvents |
| Density | 1.90 g/cm³ (approximate) |
| Smiles | CC1=CC(=CC(=C1I)C)O |
| Inchi | InChI=1S/C8H9IO/c1-5-3-7(9)4-6(2)8(5)10/h3-4,10H,1-2H3 |
| Pka | Estimated ~9.7 (phenolic OH) |
| Storage Conditions | Store at room temperature, protected from light and moisture |
As an accredited 2,6-Dimethyl-4-Iodophenol factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Amber glass bottle containing 5 grams of 2,6-Dimethyl-4-Iodophenol, sealed with a screw cap, labeled with safety information. |
| Shipping | 2,6-Dimethyl-4-Iodophenol is shipped in tightly sealed, chemical-resistant containers to prevent exposure to light, moisture, and air. The packaging complies with international and local regulations for hazardous materials. Appropriate hazard labeling and documentation are included, and the shipment is handled by certified carriers to ensure safety during transit. |
| Storage | 2,6-Dimethyl-4-Iodophenol should be stored in a tightly sealed container, protected from light and moisture, in a cool, dry, well-ventilated area. Avoid exposure to heat, open flames, and incompatible materials such as strong oxidizing agents. Clearly label the container and store it in a designated chemical storage cabinet, preferably away from incompatible substances and direct sunlight, to maintain stability and safety. |
Competitive 2,6-Dimethyl-4-Iodophenol prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615380400285 or mail to sales2@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8615380400285
Email: sales2@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Walking the line between consistency and purity requires more than just chemistry. It takes a commitment to process control, an eye for raw material selection, and care at each stage. 2,6-Dimethyl-4-Iodophenol, CAS 6627-16-9, stands out for its performance in organic synthesis and pharmaceutical research. Over the years, producing this compound has highlighted the necessity of keeping every input—from methylating agents to protective atmospheres—as controlled as the reaction batch itself. Small fluctuations in the quality of precursor phenols can steer the final outcome, affecting not only the assay but also structural reliability.
In our setup, every step is designed around traceable, high-purity input materials. We follow strict environment monitoring because airborne contaminants from older manufacturing zones sometimes seep into open-vessel syntheses. Iodination introduces its own challenges, given how volatile and reactive iodine sources can be. We lean on batch-wise vacuum checks and real-time UV monitoring during halogen introduction. Progress isn’t only technical. Only by listening to our purification crew about shifts in batch color or viscosity have we managed to peg and eliminate cross-contamination with related isomers.
Quality matters the moment a batch leaves the filter press. For 2,6-Dimethyl-4-Iodophenol, I’ve noticed research teams set strict boundaries for purity. We test each batch at >98% by HPLC. A white to slightly beige crystalline powder usually means our process hit its targets, but we learned never to let small shifts slide. If someone requests additional GC-MS analysis to rule out methylated byproducts, we run it. This habit was born from a lesson early on, after a partner flagged small aromatic impurity peaks that almost went unnoticed under standard UV.
Water content can tip the final product’s usability. Most labs ask for less than 0.5% moisture by Karl Fischer titration. Storage conditions count—an overlooked warehouse corner with excess summer humidity once reduced an entire lot’s value. Since then, double-layered drum seals and dehumidified storage have become standard. Iodinated aromatics demand respect for shelf stability, with dark amber glass or lined containers as the default. While some clients pour it straight from sealed drums into reactors, those prepping analytical standards request portioned vials with inert gas headspace. Accommodating these handling differences has been key in building trust.
Many view 2,6-Dimethyl-4-Iodophenol as a tool for introducing methyl and iodine functional groups into more complex molecules. This compound often forms part of cross-coupling reactions—Suzuki and Sonogashira couplings stand out. The presence of the iodine atom at the para position makes it a strong candidate for palladium- or copper-catalyzed transformations. The two methyls alter the electron density, sometimes steering regioselectivity or boosting yield in tricky couplings. Medicinal chemists tell us their target molecules can hinge on the reliability of these ortho methyl groups—anecdotes from feedback about batch-to-batch differences have prompted us to refine methylation controls for finer reproducibility.
We’ve seen our product move into agricultural and materials science labs too. Some of these teams chase halogenated scaffolds for fungicide precursors or venture into high-performance polymers. The breadth of application keeps us close to the latest research journals and patent filings, as well as real-time feedback. Recently, a project on phenolic resin modifiers revealed the pitfalls of trace metallic contaminants retained from older glassware. Now, every glass batch reactor undergoes acid-wash and verification to drive down background signals. These cross-discipline uses remind us that a poorly made batch can ripple downstream into wasted time and missed deadlines.
Plenty of suppliers offer aromatic iodides, but ours is shaped by what happens at every sieve, filter, and packing bench. The biggest difference comes from our hands-on process controls and the way we treat technical staff as process watchdogs. We don’t treat 2,6-Dimethyl-4-Iodophenol like an anonymous bulk chemical. The approach threads through the lot release process: every batch receives not just electronic data but handwritten sign-off from two different sections—synthesis and QC—before it moves offsite. This tradition started after we caught a rare batch fault early, thanks to a vigilant floor supervisor who recognized a slight sulfurous odor. Correcting it meant tracing back to a batch of cleaning agents, but sharing this story became part of our onboarding.
Physical form matters more than buyers sometimes realize. Occasionally, we’ve switched milling protocols to avoid excessive fines, which complicate weighing and transfer under fume hoods. We test for flow—even if the client didn’t specify—because a clumpy or electrostatically charged lot can derail automated dispensing. Many first-time users don’t think to ask about particle aggregation, but hearing from a Japanese pharma lab about clogging prompted us to revisit our drying oven ramp rates. By regularly checking downstream user habits, we sidestep many recurring headaches.
Tracking contaminants is a full-time task. Halides, trace metals, and solvent residues can undermine downstream chemistry. Early attempts to speed up output—using nitrogen alone instead of controlled argon—once led to slight product darkening on exposure. Retesting, and honest post mortem with the formulation crew, taught us that shortcuts in inert-gas blanketing aren’t worth the risk in multi-kilo runs. Each drum that passes out of our site reflects years of iterative improvement, from batch documentation to lot traceability.
Regulatory standards evolve based on what researchers and regulators report. Our familiarity with international demand means maintaining impurity profiles that track below stringent thresholds. Chlorinated solvent traces, for example, often prompt extra scrutiny for pharma intermediates. After seeing unexpected solvent inclusions flagged in Japanese import screening, we adopted a triple-solvent-exchange technique finishing step. There’s nothing theoretical about it—every corrective tweak starts with data, but only ends when the lab team, production, and QA all sign off after physical checks.
Some might imagine chemical manufacturing as a world of endless PPE and signs, but daily safety relies more on routine discipline than dramatic interventions. During scale-up, we discovered that solid chunks of 2,6-Dimethyl-4-Iodophenol in open vessels raise inhalation risk if the laminar flow curtain isn’t set right. It’s not just about labels—it’s a hundred small habits: regular filter mask changes, controlling traffic through blending bays, and posting batch-specific chemical behavior warnings for the team.
Many years back, we switched to lower static packaging wraps after a near miss with a powder flash. One operator’s insistence on using a grounded scoop—not in the procedure back then—prevented an expensive mistake. These episodes underscore that safe handling is personal, built on real feedback, and resistant to shortcuts that seem harmless until a close call proves otherwise. While safety data sheets matter, the practical expertise of people who pack, ship, and use the drums shapes every change in our operating procedures.
Research environments shift all the time, which keeps us on our toes. A few years ago, several clients asked for pre-weighed, ready-to-use aliquots. At first, we doubted whether this would warrant process retooling, but repeated requests tipped the scale. We invested in automated filling lines for small-batch packaging. This pivot had a surprise upside—it revealed micro-issues in our previous lot mixing steps that never surfaced with traditional bulk drums. Consistency took another step forward. For those synthesizing novel radiolabelled molecules, every milligram matters, and smaller packs have lowered wastage, driving better value across the chain from R&D to scale-up.
Some discoveries happen by accident: an R&D technician trying new phenol-specific stabilizers aimed to extend shelf life. After a three-month stability trial, we realized a low-dose antioxidant cut the formation of yellowing byproducts under warehouse lighting. That method is now standard for key clients whose work carries time-sensitive analytical demands. Our approach puts us shoulder-to-shoulder with those at the lab bench—we learn together with every feedback loop.
Many purchasing managers focus on price, but skilled chemists press for reliability and traceability. They want certificates that go deeper than standard product IDs, ask detailed questions about process controls, and request impurity profiles run by advanced methods. From our vantage, satisfying these questions means more than handing over a report—it means being ready to pull historical batch data, answer formula changes, and know which packing run linked to which shift supervisor. We store chromatograms, not just summary reports, because on several occasions, clients required raw data to troubleshoot their own processes. This transparency builds trust and closes knowledge gaps fast.
Another frequent request covers reactivity and side product control in downstream chemistry. The electron-donating impact of both methyl groups—one each at ortho positions—means activation of the ring for selective halogenation or coupling is a given. But each process brings risks of over-iodination or substitution. Knowing how our intermediate behaves under customer-specific conditions lets us recommend or tweak purification steps. On rare occasions, a partner flagged unexpected response in cross-couplings—they’d sourced comparator samples from a competitor that ran an older, more aggressive iodination process. Their final products showed improved NMR spectra when they switched to our material, since our slower, temperature-controlled halogenation preserves desired isomer ratios without driving side-chain rearrangements.
Selection often comes down to the difference between this compound and simple para-iodophenol or 2,4,6-trimethylated variants. The dimethylated version offers a mix of selective reactivity and stability that others don’t. It bridges the gap between raw reactivity and downstream functionalization potential for both Pd-catalyzed and Ni-catalyzed couplings. Many see higher isomeric purity in reactions starting from this molecule, especially where ortho-substitution limits undesired rearrangement.
Alternatives exist, but feedback from medicinal and process chemists suggests lower side product rates using our dimethyl-iodo derivative over unsubstituted iodophenols. In practice, less time lost to chromatography or complex purification steps means smoother workflow. In rigid timeline environments, every percent of yield and every avoided impurity challenges justify careful precursor choice. We track these outcomes closely, thanks to frequent client check-ins and post-sale technical calls.
Every complaint and compliment refines how we work. Occasional supply chain hiccups—like raw material backorders or struck ports—forced rapid adaptation. Our logistics team maintains active partnerships with forwarders who grasp the urgency of temperature or humidity control in long-haul shipping. After several hot-climate deliveries led to marginal assay drops, we switched standard shipping to include thermal protection and silica packs.
Lab support doesn’t end at delivery. If a user logs inconsistent melting points or off-color samples, we start by cross-referencing retained batch samples and run parallel reanalysis. On one occasion, secondary analytical findings spotted a rare dimer arising during a particularly humid monsoon season, prompting a review of all air handling and post-synthesis conditioning equipment. Resolving these issues deepened ties with clients, who appreciate open lines and real, technical dialogue, not generic form-letter responses.
Every lot of 2,6-Dimethyl-4-Iodophenol reflects the lessons and rigor of a team that values data, communication, and lived experience on the production floor. Success comes not from meeting the minimum specifications, but from active listening, learning from near-misses, and always striving for better process insight and client satisfaction. Chemists and researchers ask for more than just a compound—they depend on the knowledge and adaptability built into every shipment. With each improvement, every adjustment made from feedback or real-world challenge, we aim to drive the entire field forward—one well-made drum at a time.