Anhui Liwei Chemical Co., Limited
Products

O-Cresolphthaleincomplexation Indicator


    • Product Name O-Cresolphthaleincomplexation Indicator
    • Alias O-CPC
    • Einecs 241-018-1
    • Mininmum Order 1 g
    • Factory Site Lingwu, Yinchuan, Ningxia, China
    • Price Inquiry sales2@liwei-chem.com
    • Manufacturer Anhui Liwei Chemical Co., Limited
    • CONTACT NOW
    VTB
    Specifications

    HS Code

    788249

    Product Name O-Cresolphthaleincomplexation Indicator
    Chemical Formula C28H30O13S
    Molar Mass 606.60 g/mol
    Appearance Dark red to purple powder
    Solubility Soluble in ethanol and alkaline solutions
    Ph Indicator Range 8.2 - 9.8
    Application Calcium determination in water analysis
    Storage Temperature 2°C to 8°C
    Cas Number 537-58-0
    Sensitivity Sensitive to light; store away from sunlight
    Synonyms o-Cresolphthalein complexone, CPC indicator
    Stability Stable under recommended storage conditions
    Hazard Statements May cause irritation to skin and eyes

    As an accredited O-Cresolphthaleincomplexation Indicator factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing The O-Cresolphthaleincomplexation Indicator is packaged in a 25g amber glass bottle with a secure screw cap for light-sensitive storage.
    Shipping O-Cresolphthaleincomplexation Indicator is shipped in tightly sealed, chemical-resistant containers to prevent contamination and moisture absorption. The package is clearly labeled, adhering to all relevant hazardous material regulations. It is transported under controlled conditions, avoiding extreme temperatures and direct sunlight. Shipping includes safety documentation and material safety data sheets for safe handling.
    Storage O-Cresolphthaleincomplexone indicator should be stored in a tightly closed container, protected from light and moisture, at room temperature (15-30°C). Keep it in a dry, well-ventilated area away from incompatible substances, such as strong acids and oxidizers. Avoid exposure to extreme heat. Label containers clearly and ensure that only trained personnel handle this chemical indicator.
    Free Quote

    Competitive O-Cresolphthaleincomplexation Indicator prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615380400285 or mail to sales2@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615380400285

    Email: sales2@liwei-chem.com

    Get Free Quote of Anhui Liwei Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    O-Cresolphthaleincomplexation Indicator: Trusted Choice for Precision Calcium Determination

    What We Offer as the Manufacturer

    Experience in chemical manufacturing shapes every batch of O-Cresolphthaleincomplexation Indicator that leaves our facility. We understand what happens on lab benches when chemists face unclear endpoints or finicky indicators. As those who synthesize this reagent in-house, we care just as much about stability, solubility, and purity as the people lining up their burettes and calibrating their spectrophotometers.

    We synthesize this compound with attention to detail refined over years of small adjustments and scaled-up syntheses. With each lot, raw materials come under scrutiny for trace contaminants. Solvent selection, temperature control, and filtration carry equal importance. Our production skips unnecessary steps, focusing on consistency between lots. The powders we ship have distinct pink-violet coloration and dissolve easily in ethanol or alkaline solutions—traits we watch for, batch after batch. Spectral purity checks and Colorimetric performance define release, not wishful thinking.

    O-Cresolphthaleincomplexation Indicator: Model and Specifications

    Our standard product runs under the model name OCPC-200, reflecting a purity of over 99%, verified through both chromatography and UV-Vis spectrometry. We optimize grain size to reduce clumping, using sieves and flow-agent adjustments drawn from decades of feedback from analytical chemists. Each container leaves with moisture content below 0.3%, protecting from hydrolysis—an enemy of shelf life for this class of dye-indicators. Customers looking closely at flow properties or color intensity under specific conditions get application-focused, real-world support grounded in practical lab experience.

    Each batch ships with documentation confirming quality checks. Our material matches the chemical formula C28H30O4, also listed as 3,3-Bis[4-hydroxy-2-methylphenyl]-1,1-dimethylurea, which aligns with the international standards recognized by major laboratory protocols. We listen to users working daily with titrations needing endpoints around pH 8.1-10.0. Other customers request confirmation of compatibility with modern clinical analyzers for serum calcium determinations—a need we understand from decades of technical support.

    Applications in Laboratories and Industry

    O-Cresolphthaleincomplexation Indicator isn’t just another dye in a bottle. In practical use, it has become the foundation for colorimetric methods that measure calcium in water, milk, serum, pharmaceuticals, and fertilizers. In clinical testing, its distinct violet-red color change—produced as calcium ions form a stable chromophore complex with the OCPC molecule—streamlines endpoint detection. Unlike indicators prone to drifting or subtle hues, this one shows a clear transition, helping analysts avoid over-titration or missed endpoints. That certainty helps ensure patient safety, process control in plant nutrition analysis, and accuracy in environmental test labs.

    Labs qualify new indicator lots before integrating them into their routine calcium determination. Some standardize per protocol, blending OCPC into alkaline solutions before use in automated chemistry analyzers. The color shift under controlled conditions—often checked at around 570-580nm on a spectrophotometer—lets technicians keep results consistent without searching for unclear color changes. Trace impurities can throw off these results, which is why each lot faces secondary testing in simulated clinical and industrial samples.

    In our work with instrument manufacturers, we adapt the indicator's presentation format to suit automation, pouring years of feedback into each finer adjustment. Tablet and lyophilized presentations remain stable on benchtops. Bulk powder offers flexibility for those with custom buffer systems or unique dispensing setups. Quality teams get transparency on every aspect, from batch homogeneity to interaction with anti-coagulants or surfactants common in clinical analyzers.

    What Sets OCPC Apart: Direct Experience

    After thousands of conversations with those using methylthymol blue, calmagite, or even Eriochrome Black T, we see specific limitations with classic indicators in calcium measurement. Some don’t provide a clear enough endpoint. Others bind loosely, giving sluggish color changes or raising background interference. O-Cresolphthaleincomplexation Indicator tackles calcium with higher selectivity than most, resisting interference from magnesium under most common conditions.

    We monitor the market for raw materials and packaging improvements. Customers tell us that dye stability isn’t just a claim on a spec sheet—it’s tested every time a technician opens a bottle that was shipped half a world away, or sat through a humid summer. By investing in moisture barrier packaging and verifying each container’s seal before shipping, we reduce those “bad surprise” moments. If a problem crops up, users get a fast response, supported by the same staff handling the technical details and synthesis steps.

    Old titration manuals mention phenolphthalein and other classical dyes. We’ve run real-world trials where phenolphthalein won’t show a color change until pH creeps above 9.5—too late for many calcium determinations. By contrast, our indicator offers a color shift right at the critical pH typically required by modern calcium assays, cutting out the ambiguity. Calmagite and Eriochrome Black T show more interference from metals like magnesium and iron, pushing chemists toward extra masking agents. We’ve tested our OCPC indicator in the presence of these ions and publish full details of performance with common interferences, rather than leaning on out-of-date literature.

    No Shortcuts in Quality Control

    Every chemist remembers at least one big test ruined by poorly characterized indicators. We keep this in mind at each stage, from solvent picking to blending. Old industry habits sometimes rely on visual checks, but we pair this “eye test” with HPLC data, colorimetric assays, and residual solvent analysis. Batches that don’t meet the spec don’t leave our lab. Our technical team works face-to-face with customers, walking through steps for adapting OCPC to legacy protocols or adjusting for particular instrument systems.

    We tune our process to ensure each gram of OCPC meets low moisture and high color intensity criteria, a response to feedback from labs reporting sluggish solubility or fading endpoint color from lesser sources. Where required, we provide the SAT (System Applicability Test) support documentation covering sample stability and interference data. Some users ask about using OCPC for magnesium, strontium, or rare earth metal titrations. We encourage careful testing in such cases: our direct data demonstrate high calcium selectivity, but customers with advanced needs get application support grounded in actual test results, not just literature citations.

    Supporting Chemists and Their Results

    In the practical world of water analysis, dairy inspection, and clinical diagnostics, labs balance accuracy with regulatory requirements and budget constraints. We engage with these users directly, tracking their feedback through sample kits and ongoing tech support. Their real-world challenges shape both our product and our documentation, keeping us honest and focused on what matters.

    Whenever a regulatory agency tightens tolerances for measurement or shifts towards green chemistry standards, we adjust process chemistry and packaging accordingly. We have swapped certain solvents or adjusted reagent impurity specs to keep pace with requirements as set by organizations like AOAC, ISO, and USP. We never treat compliance as a box-ticking exercise: the goal stays centered on helping end users meet both their accuracy targets and health/safety obligations without tradeoffs.

    Feedback loops with analytical scientists drive everything from particle size refinement to the addition of anti-caking agents approved for food and clinical use. As an example, recent years brought changes to packaging based on user input around dustiness and pourability, leading us to refine bulk-dose containers and single-use sachets. Each change stems from practical testing—the sort where industrial labs stress-test a material beyond what the standard protocols enforce.

    Safety, Handling, and Practicalities

    Safety goes beyond printing SDS sheets or lock-step adherence to local regulations. As the team handling OCPC from crude to packaged form, we interact daily with the practical issues surrounding dye indicators—workshop spills, dust formation, handling during titration. Early on, we switched to low-dust formulations for some clients in high-throughput labs, reducing cleanup and exposure. Our work on improving irritant labeling, practicing robust PPE standards, and participating in industry dialogs on non-toxic alternatives all feed into what appears as a simple pink-violet powder.

    Users in teaching labs report concerns about eye and skin exposure, so we support both labeling and custom safety training where requested. Professional users in clinical settings want confirmation that everything entering an analyzer holds minimal risk for contamination or cross-reaction with patient samples. These requests drive our ongoing investment in documentation test methods and safety audits.

    For those working in humid or tropical climates, we publish clear shelf-life expectations and practical steps for keeping indicators dry—simple, proven steps drawn from the decades we’ve stored and handled these dyes ourselves in production settings. We encourage users to avoid common missteps, like resealing containers with wet gloves, and provide anti-humidity packets in every supply.

    Supporting Innovation: From Bulk Shipments to Automation-Ready Formulations

    Labs aren’t static. Across Asia and Europe, water testing has grown automated, and food production labs now integrate OCPC into robotics and high-throughput analyzers. Our operation adapts to these trends not by guessing at needs, but by partnering with the engineers behind new devices. Increasingly, we ship OCPC as both powder and pre-measured, automation-ready tablets. The chemistry remains steady, but the presentation follows the evolution of technology.

    Instrument developers need assurances beyond bulk purity—they need to know indicator blends will remain stable in pneumatics, that no dust will mess with fine measurement optics, and that reagent cassettes will keep color and consistency for every test run. We respond by testing OCPC in partnership with these developers, publishing methods, and validating performance on their specific platforms. This hands-on back-and-forth—whether with a small QA team on a new automated analyzer, or a multinational seeking a reliable source—drives our continual improvement.

    We maintain traceability for every shipment, from sourcing through synthesis, quality check, and logistics. End-users can track back from a problem sample to its raw material batch. This is not just compliance: it's an embedded practice, so incidents get solved with data and truth, not endless finger-pointing. True support doesn’t come from a call center—it comes from the chemists and production staff who built the product in the first place.

    Towards a Greener and More Reliable Future

    Interest in green chemistry and less toxic indicators grows each year. We keep pace by evaluating both established and experimental complexation indicators—testing dye breakdown, toxicity, and residue in environmental matrices. We also participate in working groups developing lower environmental impact protocols, making sure that any OCPC released meets not just performance needs, but also steps forward in environmental stewardship.

    In scaling production, we’ve adopted waste minimization practices: recycling solvents, energy recovery during synthesis, and careful batch scaling. We do not advertise as “eco-friendly” before facts support the claim; we publish our progress and invite users and peer reviewers to judge for themselves. Where alternatives exist—either for less risky handling or waste reduction—we run comparative studies and introduce changes transparently.

    Users trust us to provide open documentation on dye degradation, residual solvent analysis, and heavy metal testing, conscious of tighter regulatory scrutiny across clinical and water-testing industries. We add method updates regularly as new international guidelines emerge.

    Summary: Why Decades in Manufacturing Makes a Difference for Your Lab

    Decades spent manufacturing O-Cresolphthaleincomplexation Indicator show up in the details—the clarity of the endpoint, the consistency across bottles, and the reliability in automated systems as much as classic flasks. Lab chemists, educators, QC specialists, and process engineers all benefit when each gram of indicator performs just like the last. We keep open lines with customers, evolving the product to handle new testing challenges and data-driven feedback. This work extends far beyond supplying a bottle of dye—it’s a partnership aimed at keeping calcium measurement honest, precise, and confidently in the hands of the analysts who depend on it.