HS Code |
653537 |
| Chemical Name | O-Cresolphthalein Complexone |
| Cas Number | 2411-89-4 |
| Molecular Formula | C28H22N2O7 |
| Molecular Weight | 498.49 g/mol |
| Appearance | Dark reddish-purple powder |
| Solubility | Soluble in alkalis, slightly soluble in water |
| Melting Point | Above 300°C (decomposes) |
| Ph Indicator Range | 9.3 - 11.0 |
| Storage Temperature | Room temperature |
| Application | Calcium determination in clinical analysis |
| Synonyms | CPC, 4,4'-(3,3-dimethyl-1-phenolphthalein-4,4-diyl)bis(2,6-dimethylphenol) |
| Purity | Typically ≥95% |
| Absorption Maximum | 575 nm (in alkaline solution) |
As an accredited O-Cresolphthalein Complexone factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | O-Cresolphthalein Complexone, 25g, is packaged in a sealed amber glass bottle with a detailed hazard and usage label. |
| Shipping | O-Cresolphthalein Complexone is typically shipped in tightly sealed containers to prevent moisture absorption and contamination. Packaging complies with chemical transport regulations, and labeling includes hazard identification and handling instructions. The chemical is usually shipped at ambient temperature, with care taken to avoid strong light or excessive heat during transit. |
| Storage | O-Cresolphthalein Complexone should be stored in a tightly sealed container, protected from light and moisture. Keep it in a cool, dry, and well-ventilated area, away from incompatible substances such as strong oxidizers and acids. Store at room temperature (15-25°C) and ensure the container is properly labeled. Follow all applicable safety guidelines when handling and storing this chemical. |
Competitive O-Cresolphthalein Complexone prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615380400285 or mail to sales2@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8615380400285
Email: sales2@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
On our production floor, every batch of O-Cresolphthalein Complexone draws from over two decades of experience refining reagents for analytical chemistry. Our own lab staff use the very material we manufacture, so we care about consistency, purity, and genuine batch-to-batch reliability. This compound, easily recognized by its deep red-violet hues in alkaline media, is mostly known for its use as an indicator and chelating agent in complexometric titrations—especially for calcium determination in clinical, water, and food analysis. The work doesn’t end with meeting a published standard. Each shift at our plant involves continuous monitoring for purity and color strength, much like a chef tastes sauces in their own kitchen.
Customers often ask what distinguishes one producer’s O-Cresolphthalein Complexone from another’s. As a chemical manufacturer, differences appear unfiltered: the presence or absence of side-products, not just on a chromatogram but in subtle shifts of color development. Our plant’s reactors are set up specifically for small-batch synthesis; that lets us control the temperature profile and mixing time closely. These factors reduce impurity load, which is crucial in assays requiring sharp endpoint detection. Where traders and repackagers discuss fit for application, manufacturers see every gram’s potential impact—especially in sensitive diagnostic protocols.
This attention grows from first-hand experience troubleshooting unexplained endpoint drift for water analysis labs. We’ve analyzed our competitors’ lots—finding residual sulfonated byproducts and traces of phenol red, interfering at low calcium concentrations. This motivates us to extend purification steps, add in-process QA, and act on feedback from users at research and hospital labs. Our product profile aims for unsurpassed purity and chromatic intensity, confirmed using in-house spectroscopic data as well as practical titration performance.
In chemical advertising, purity often gets a number—99%, 99.5%—as if that settles the matter. We see purity as only one slice of the story. Spectral profile, hygroscopicity, solubility behavior in carbonates, particle size, and even flow characteristics matter for the bench chemist and the automated analyzer alike.
Our O-Cresolphthalein Complexone is available in powder form, tightly controlled for low water content. Dehydration levels make a difference in weighing operations and also prevent clumping or caking after shipments cross humid regions. We take regular Karl Fischer readings to monitor this. Over the years, researchers have shared stories of ruined calcium assays due to poorly handled, moisture-contaminated lots from other sources. This kind of feedback pushed our team to invest in new drying and packaging lines, keeping this reagent in optimal condition as it leaves our warehouse.
Particle size distribution deserves a mention here. Automated dispensers in high-throughput analyzers can jam on oversized or irregular granules. We tune our milling process to provide a powder with predictable flow—not just for customers’ convenience, but for accuracy and reproducibility in the lab. Our process targets a median particle size that swings smoothly between weighing boats and pipettes, reducing static cling and loss.
A few years ago, a diagnostic lab described inconsistent color development during a critical batch of blood calcium assays. They sent samples of both the water and their indicator—our O-Cresolphthalein Complexone, as well as one purchased from an overseas reseller. We ran these through our own lab: only the reseller’s product showed a persistent bluish cast at high pH, pushing measured calcium levels off by up to 10%. Looking at their material, we saw trace iron and aromatic contaminants. Our team upped quality checks for metal traces using ICP-OES techniques across all new batches, setting stricter internal limits than any published pharmacopeia standard.
We also routinely review dissolution behavior. Fully soluble products make for easier calibration of colorimetric readings. We’ve seen poorly handled batches from generic importers leave residues, affecting the path length in cuvette-based analyzers and shifting results. In these cases, as a primary maker, we have the data and production flexibility to implement feedback quickly. We swapped glass-lined reactors for stainless to eliminate a source of trace metals a decade ago, reducing failed QC events.
For calcium determination, O-Cresolphthalein Complexone offers distinct advantages over classic indicators like methylthymol blue or Arsenazo III. Its deep color change boosts sensitivity for low-concentration measurements in clinical samples. With the right buffer, it shows less interference from magnesium—a key point for blood serum analysis.
On the industrial scale, some labs experiment with alternative reagents to cut costs, but these substitutes often demand more complex handling or involve longer assay calibration times. Spectroscopic selectivity and color strength are not abstract points; they mean less background noise in the measured signal, fewer retests, and more reliable reporting. That’s feedback from users who report on job-critical turnaround time and regulatory compliance, not just cost per kilo.
Unlike some EDTA-based procedures, calcium detection using our indicator avoids false positives from other polyvalent ions. The color transition is sharp and easily interpreted even for less experienced technicians—a real asset for high-throughput hospital environments pressed for time and accuracy.
After shipping an order, our involvement doesn’t end. Our technical support line connects users to real staff with direct access to the people who oversee manufacture, not just customer service scripts. Issues raised, whether cloudiness on dissolution or unexpected endpoint lag, get walked back through production records and batch test data. Laboratories have often traced “mystery problems” to material supplied by traders relying on generic reshipments. Direct purchase from us brings not just documentation, but transparency into our raw material selection and production logs.
Our plant sources phenolphthalein and cresol directly from secure, audited suppliers, limiting variability from the start. Raw material authentication takes place in-house, including NMR and HPLC analysis for identity and purity. Trace-metal contamination—often a silent culprit in endpoint instability—gets resolved with refined filtration and vessel selection. Feedback cycles between production and application staff keep us nimble, letting us respond to changing analytical trends.
Laboratory protocols and government guidelines shape the performance targets for every batch. Our facility aligns with the most current guidelines for medical, water, and food analysis. Many laboratories have to document strict traceability and QA controls, including lot-specific performance graphs or secondary standardization. We maintain multi-year records of batch data and retain samples from each production run, making post-market review possible.
End users in diagnostics look for proof beyond a data sheet. We’re ready and able to support users with additional COA data—trace metal panels, stability curves, batch-specific UV-Vis spectra. School and university labs sometimes run advanced practical experiments requiring colorimetric calibration or kinetic monitoring; our technical team shares known methodologies, not just commercial bullet points.
Research in environmental analysis leans heavily on the reliability of O-Cresolphthalein Complexone for measuring hard water samples. Some provincial authorities request specification support for field testing protocols or alternate packaging. Adjusting to these priority shifts is easier as a direct manufacturer; we can implement special requests into active production runs after review.
O-Cresolphthalein Complexone isn’t just another powder tossed on a shelf. Moisture and light exposure degrade its performance far quicker than many expect. We ship in UV-blocking, desiccated containers. Our own QC team regularly stresses stored batches under less-than-ideal warehouse conditions to build realistic expiry dates—none of our current packaging formats claim longer shelf life in the abstract, only what our stress tests confirm.
Some labs claim reusing open containers for a year or longer; we’ve directly observed chromatic fade and endpoint slippage by the six-month mark in repeated open-close cycles, especially in humid seasons. We take this experience back into packaging design—currently, our high-barrier pouches help slow moisture migration for partial-use customers.
As a direct producer, we’re alert to the details: after several humidity complaints from tropical regions, we modified inner sealing specs and now include fresh desiccant packs in every lot. This isn’t standard across suppliers; resellers rarely have direct control over packaging or warehouse climate.
High-volume laboratories often process thousands of calcium tests each day. These users spot inconsistency quickly—whether in powder handling, batch-to-batch calibration, or endpoint sensitivity. We’ve worked directly with environmental agencies and contract food labs to deliver large-volume packaging support, keeping the product stable through broad temperature and humidity ranges.
Our team regularly runs scenario stress tests, cycling product through high-heat and chill-shock conditions before batch release. This practice started after a food lab reported non-uniformity in color yield that we traced to shipping delays and temperature swings en route. These lessons carry forward into production—our staff now confirm both product and packaging stand up to long-haul and export demands.
Feedback isn’t just welcome, it sparks process improvements. An agricultural lab challenged us to match purity levels required for GMO crop screening, even after six weeks outside refrigeration. Results from those tests led us to adopt new antioxidant protocols during final drying, reducing product breakdown rates and lengthening shelf stability.
Sourcing from the chemical manufacturer, rather than a generic distributor, marks a visible difference in lab operations. Each batch leaving our facility carries full traceability from raw material lot to finished product. We see direct evidence of this in user labs: product sourced elsewhere sometimes displays unexpected solubility traits, or less consistent color formation across dissolution runs. Lives depend on reproducibility, particularly in the diagnostics sphere.
Our communications stay open after sale. Teams facing unusual titration profiles or limited color differentiation get walk-through help; requests for documentation or batch data go straight to production records. We’ve bought back competitor samples for comparison, checking them against our in-house standards. Variability in product hue, granularity, and endpoint detection comes out clearly. Only hands-on makers can implement targeted fixes for these issues, while resellers have no direct lever over batch production or QA protocols.
Scientists developing new protocols—whether for microfluidic calcium tests or innovative colorimetric sensors—often work closely with us to optimize for reagent lot consistency. We offer pilot samples from in-progress batches, speeding up the R&D loop. Our production chemists get direct exposure to current research, helping us adjust process parameters for emerging analytical needs.
This direct line to manufacturing knowledge is not an abstraction but a day-to-day exchange. Technical issues raised by R&D teams—whether solubility at microdose, color intensity at new detection limits, or storage stability under field conditions—translate into real process tweaks. Our ongoing partnerships change how we fine-tune synthesis, drying, or final formulation steps.
As regulations on laboratory materials tighten worldwide, the focus moves from headline purity numbers to total reproducibility and regulatory transparency. We keep pace with those expectations. Each package of O-Cresolphthalein Complexone embodies our commitment as a direct producer—combining frontline chemistry practice, robust industrial controls, and an ear tuned to the feedback of practical laboratory use.
O-Cresolphthalein Complexone will remain vital in analytical chemistry so long as accurate calcium quantification is needed for blood, food, and environmental safety. New detection technologies appear each year, but the underlying chemistry demands the same sharp color response, low contamination profile, and steadfast handling under real-world conditions.
By holding quality in our own hands, staying responsive to chemists’ actual needs, and treating feedback as the main source of innovation, we support thousands of labs worldwide. No trader or distributor can claim such close involvement with the material they sell. If you work with O-Cresolphthalein Complexone, a manufacturer’s perspective becomes an asset, not just in batch-to-batch trust—but in pushing chemistry forward, together.